Page 104 Manager Manual for the CD72/95/15001
Message Description
Alarm is reset
The system cannot be disarmed except between the start and stop time of the
timeslot. The system can only be reset in the event of an alarm.
Area n Arming
The warning time for area n has started. The system must be armed before the
warning time expires.
Area n Timeslot
Area n cannot be disarmed except between the start and stop time of the
timeslot. This message appears when the code is entered.
Auto ArmArean
The warning time for area n has started. After the warning time the system will
arm automatically.
Call engineer
An engineer reset is necessary. The client cannot arm until this has been done
Change code NOW!
The code will be deleted in 5 days unless the code is changed before then.
Dialler EEPROM
A fault has been found in the programming data in the dialler
Disarm Not Poss.
It is not possible to disarm with this code
EEPROM xxx
There is a fault in the programming data in the panel. xxx is a number indicating
which parts of the programming have a problem. This number may consist of
the following options (by adding up):
xxx fault
1 In zones and outputs (not the names)
2 In programming of separate systems
4 In programming of system options
8 In user codes, engineer code and U/D codes (not the names)
128 During EEPROM read or write operation
Fault
The new code entered already exists or has not been authorised
nnnTZone name
During display of open zones. The zone has had a tamper. A double loop
connection has been used.
Nd-No Panel Data
The control panel is receiving no more data from the panel
No Access
This code grants no access or the code has been entered too slowly
No Ack detect.
During manual test report. The dialler sees no acknowledgement of the report.
Possibly wrong protocol
No Arm:Walk Test!
The system cannot be armed before a complete walk test has taken place.
No dialling tone
During manual test report. The dialler detects no dialling tone
No handshake
During manual test report. The dialler does not receive a handshake. Possibly
wrong telephone number or wrong report bank/protocol
No Preference
No extended access is requested or a system is still in triggered state (only in a
split system)
Not authorised
The required bridging has not been authorised
Remote Supply An ‘Auxiliary Power’ input has been disrupted
RKP blocked The control panel has been blocked via an ‘RKP unusable’ zone
RKP fault
One or more control panels/expanders are no longer reacting
Syst Busy
An operation is still busy on another control panel
Timeslot Disarm
A user code is blocked by the timer.
U/D busy
An up/download connection has been made
Verify
Enter your code again (to verify a new or changed code)
Walk Test Required!
A walk test must be carried out.
Table two. Other messages in the display